OTHER ELECTRONIC UNITS
PROGRESSIVE HIGROSTAT PH-2
PH-2 is universal purpose microprocessor progressive HYGROSTAT with measuring range from 0-99.9% of relative humidity. PH-2 is controlling moisture into curing barn toward to wanted (programmed) humidity RH1 & RH2 and during time. The humidity in barns is increased or decreased from RH1 to RH2 in given time .
![PH2](http://www.asel.hr/en/wp-content/uploads/sites/2/2015/11/PH2.jpg)
PH2 have two work mod options:
-Automatic mod – in this mod device measure relative humidity,temperature and regulates relative humidity.
-Maunual mod – in this mod device measure relative humidity, temperature but there is no automatic regulation of humidity. Regulation of relative humidity can be performed with manual opening throttle.
![separator-ads](http://www.asel.hr/en/wp-content/uploads/sites/2/2015/11/separator-ads.jpg)
HIGROMETAR HVT-1
For measuring humid temperature with temperature sensor (5,0m of cable)
-measuring resolution of humid temperature : 0,1oC;
-measuring range of humid temperature : od 0–99.9oC
![separator-ads](http://www.asel.hr/en/wp-content/uploads/sites/2/2015/11/separator-ads.jpg)
HIGROSTAT HVT-2
For measuring humid temperature with temperature sensor (5,0m of cable) – Outputs for servo drive.
-measuring resolution of humid temperature : 0,1oC;
-measuring range of humid temperature : od 0–99.9oC
![separator-ads](http://www.asel.hr/en/wp-content/uploads/sites/2/2015/11/separator-ads.jpg)
HIGROMETAR HRV-1
For measuring relative humid with relative humid microprocessor sensor (5,0m of cable)
-measuring resolution of relative humid : 0,1%;
-measuring range of relative humid : od 0–100%
![separator-ads](http://www.asel.hr/en/wp-content/uploads/sites/2/2015/11/separator-ads.jpg)
HIGROSTAT HRV-2
For measuring relative humid with relative humid microprocessor sensor (5,0m of cable) – Outputs for servo drive.
-measuring resolution of relative humid : 0,1%;
-measuring range of relative humid : od 0–100%
![separator-ads](http://www.asel.hr/en/wp-content/uploads/sites/2/2015/11/separator-ads.jpg)
MJERAČ MTV-1
For measuring relative humid and dry temperature with humid microprocessor temperature sensor (5,0m of cable)
-measuring resolution of relative humid : 0,1%;
-measuring resolution of dry temperature : 0,1oC;
-measuring range of relative humidity : 0–100%
![separator-ads](http://www.asel.hr/en/wp-content/uploads/sites/2/2015/11/separator-ads.jpg)
REGULATOR RTV-3
For regulation of relative humidity and measuring dry temperature with relative humidity microprocessor sensor (5,0m of cable)
Ima izlaze za servomotor.
-measuring resolution of relative humid : 0,1%;
-measuring resolution of dry temperature : 0,1oC;C
-measuring range of relative humidity : 0–100%